Optimising outcomes

Data from devices that measure the posterior cornea improve

Optimising outcomes
Cheryl Guttman Krader
Cheryl Guttman Krader
Published: Thursday, March 1, 2018
The development of regression formulas that take into account posterior corneal astigmatism (PCA) has improved refractive outcomes with toric IOL implantation. But because the regression approaches use a population average for PCA and there is scatter in the population, better results should be achieved using patient-specific data, reported Thomas Kohnen MD, PhD, FEBO, at the XXXV Congress of the ESCRS in Lisbon, Portugal. Currently, there are several technologies that can directly measure PCA. Prof Kohnen discussed the use of Scheimpflug tomography (available from Oculus and Ziemer). “Precise refractive outcomes are critical for meeting patient expectations for good uncorrected vision with toric IOLs. Traditionally we used instruments that measure only anterior corneal power, and the role of the posterior cornea in total corneal refractive power (TCRP) was dismissed because of the small difference between the indices of refraction of the cornea and aqueous,” said Prof Kohnen, Professor and Chair, Department of Ophthalmology, Goethe University Frankfurt, Germany. “Due to the effects of the posterior corneal surface and corneal thickness, there might be large differences between SimK and TCRP. Neglecting the PCA may lead to a significant deviation in corneal astigmatism estimation in a proportion of eyes. I think it is good that we now have several devices for measuring PCA,” said Prof Kohnen. In a published study, Prof Kohnen and colleagues evaluated the repeatability of measurements obtained with a Scheimpflug tomographer. They reported that it generated the most repeatable anterior cornea astigmatism data compared with two different keratometers and two different Placido ring topographers. Total corneal refractive power measurements obtained with the Scheimpflug device also showed good repeatability. He also presented some case examples and reviewed three other studies using a Scheimpflug device that underscore how use of anterior cornea measurements alone can under or overestimate TCRP, depending on the type of anterior cornea astigmatism that is present. “Especially when the axis of the anterior surface is not with-the-rule, there might be a large discrepancy between the axis of corneal astigmatism between the anterior and posterior surface,” Prof Kohnen said. Data from two of the studies using Scheimpflug tomography showed that the mean magnitude of posterior cornea astigmatism is about -0.3D. Multicolour LED Douglas D Koch MD provided an overview of experience with a multicolour LED topographer (Cassini, i-optics). The topographer is reflection-based, ray-tracing technology that evaluates the posterior surface of the cornea using 2nd Purkinje imaging technology. Because it is based on reflection, not scanning, there are no movement artefacts. “To me, this technology uses the most accurate method for measuring corneal curvature to date, and it uses an interesting approach for measuring posterior corneal curvature,” said Dr Koch, Professor and Allen, Mosbacher, and Law Chair in Ophthalmology, Baylor College of Medicine, Houston, USA. “We are using it more in our practice and finding it to be very valuable. In the future I think the multicolour LED topographer will be a good fit for toric IOL calculations and for addressing other unsolved challenges in measuring corneal power.” Dr Koch noted that while the device was somewhat cumbersome to use initially, it has become much easier subsequent to hardware and software improvements. He presented some examples showing how to apply the total corneal astigmatism measurement obtained using the multicolour LED topographer into practice and how using the data it provides rather than readings from optical biometry would lead to a more accurate refractive outcome. While he is planning a systematic study to compare outcomes of toric IOL implantation using the multicolour LED topographer measurements versus regression formulas, he cited a retrospective study conducted by Elizabeth Yeu MD showing evidence of its benefit. In consecutive series of eyes, Dr Yeu reported residual refractive astigmatism was <0.5D in 84% of 50 eyes when calculations were performed using the Baylor nomogram and in 95% of 74 eyes when IOL power was selected based on the multicolour LED topography data, Dr Koch said. Thomas Kohnen: kohnen@em.uni-frankfurt.de Douglas D Koch: dkoch@bcm.edu
Tags: astigmatism
Latest Articles
From Lab to Life: Corneal Repair Goes Cellular

Long-awaited cellular therapies for corneal endothelial disease enter the clinic.

Read more...

Balancing Innovation and Safety

Ensuring access to advanced cell therapies amid regulatory overhaul.

Read more...

With Eyes on Its Future, ESCRS Celebrates Its Past

Winter Meeting offers opportunities to experiment with new concepts and formats.

Read more...

Best of ESCRS Winter Meeting 2024

Read more...

Following the New Generation

EDOF IOLs an option for eyes with mild comorbidities, showing potential in mini-monovision strategies.

Read more...

Refocus on Multifocals

Trifocal IOLs continue to improve as consensus grows regarding indications and contraindications.

Read more...

Common Myths in Presbyopia Correction

Patient education key to satisfaction with refractive IOLs.

Read more...

Reversible Multifocality

Two-lens combination offers low-risk spectacle independence for cataract patients and presbyopes.

Read more...

Managing a Cataract Surgery Refractive Miss

Weighing the pros and cons of options for intraocular intervention.

Read more...

Unleashing OCT’s Full Potential

Performance of newest tool for corneal evaluation meets or beats older standard technologies.

Read more...

;