ESCRS - Stable Fixation ;
ESCRS - Stable Fixation ;

Stable Fixation

Scleral fixation of aspheric plate-haptic lens produces good visual outcome

Stable Fixation
Roibeard O’hEineachain
Roibeard O’hEineachain
Published: Friday, September 30, 2016
cataractrefr-lens-white A new small incision scleral fixation technique for eyes lacking capsular support can provide good results with implanting the Acriva UDM 611 (VSY Biotechnology) foldable plate-haptic intraocular lens (IOL), with reduced surgery time and complications, along with excellent centration and stability with good visual results, according to a study conducted by Hasanov Jamil V MD, Zarifa Aliyeva National Eye Centre, Baku, Azerbaijan. “The use of plate-haptic design versus C-loop haptic design eliminates complications such as: suture slippage or entangling, IOL-donesis, tilting, decentration, and possibility minimising manipulation in the anterior chamber during IOL implantation,” Dr Jamil told EuroTimes in an interview. In his study, Dr Jamil performed cataract surgery in four eyes of four patients with a mean age of 47.75 
years (range 23-70) using 2.4mm incisions and a modified trans-scleral suturing, to implant the Acriva UDM 611 plate-haptic foldable IOL. He noted that, in addition to its ultra-definition aspheric optic, the lens has a unique haptic design which makes it particularly suitable for small incision trans-scleral fixation surgery. At six months follow-up, best corrected visual acuity ranged from 20/100 to 20/25, compared to 20/800 to 20/40, preoperatively. In addition, the IOL achieved excellent centration and stability in all eyes. Rapid postoperative recovery and minimal induced astigmatism were observed. He noted that those findings have held up since the six-month assessment and that he has achieved similar results with a further 
25 patients who underwent the surgery, he said. When performing the procedure, Dr Jamil first creates two 3.0mm-wide corneoscleral pockets at 3 and 9 o’clock. Then he threads a10/0 prolene suture through the eyelet of each haptic using two needles each, and loads the needles and the lens into the cartridge, with the tips of the needle extending outside of the cartridge. He then creates a 2.4mm clear corneal incision, through which he first places the needles with the suture, drawing them out though the corneoscleral pockets, where, after injecting the lens into the anterior chamber he securely sutures the haptics in place and completes the procedure by closing the scleral pockets. “This approach allows for a faster procedure than a traditional triangular flap procedure, because there is no conjunctival dissection or scleral cautery. In addition, it is easier to perform dissection and induces less astigmatism. In addition, the healing period after surgery is very rapid,” Dr Jamil said. Hasanov Jamil V: jgasanov@yahoo.com
Latest Articles
From Lab to Life: Corneal Repair Goes Cellular

Long-awaited cellular therapies for corneal endothelial disease enter the clinic.

Read more...

Balancing Innovation and Safety

Ensuring access to advanced cell therapies amid regulatory overhaul.

Read more...

With Eyes on Its Future, ESCRS Celebrates Its Past

Winter Meeting offers opportunities to experiment with new concepts and formats.

Read more...

Best of ESCRS Winter Meeting 2024

Read more...

Following the New Generation

EDOF IOLs an option for eyes with mild comorbidities, showing potential in mini-monovision strategies.

Read more...

Refocus on Multifocals

Trifocal IOLs continue to improve as consensus grows regarding indications and contraindications.

Read more...

Common Myths in Presbyopia Correction

Patient education key to satisfaction with refractive IOLs.

Read more...

Reversible Multifocality

Two-lens combination offers low-risk spectacle independence for cataract patients and presbyopes.

Read more...

Managing a Cataract Surgery Refractive Miss

Weighing the pros and cons of options for intraocular intervention.

Read more...

Unleashing OCT’s Full Potential

Performance of newest tool for corneal evaluation meets or beats older standard technologies.

Read more...

;