New vitrectomy probe

New tool is faster and safer

New vitrectomy probe
Cheryl Guttman Krader
Cheryl Guttman Krader
Published: Tuesday, February 28, 2017
 Stratos Gotzaridis MD Stratos Gotzaridis MD
A new vitrectomy probe featuring novel geometry and an ultra-high cutting speed will enable vitreoretinal surgeons to perform manoeuvres with greater safety, said Stratos Gotzaridis MD at the 16th EURETINA Congress in Copenhagen, Denmark. The ULTRAVIT® 10k (Alcon) probe has a bevelled tip and delivers 10,000 cuts per minute (cpm) via dual pneumatic drive technology in 23, 25+, and 27+ gauge series. It is used with the CONSTELLATION® Vision System (Alcon) with the CR4 premium software upgrade. “When performing vitrectomy, we try to remove as much vitreous as possible. However, we face a dangerous situation when the cutter comes too close to the vitreous base or over an area of detached retina. By increasing the cut rate as high as possible and decreasing the aspiration rate, we can try to protect the retina. Personally, I also hold my breath, ask my assistant to cross his fingers, and ask the scrub nurse to say prayers, thinking that every little bit might help under the circumstances,” said Dr Gotzaridis, Director of the “My Retina Athens Eye Center”, Athens, Greece. NOVEL DESIGN “With its novel design and higher cut rate, this new vitrectomy probe allows the cutting port to get closer to the retina but protects the retina to minimise complications. Its faster cut rate reduces traction and therefore the risk of iatrogenic tears, and it reduces resistance to flow because it takes smaller size bites.
With its novel design and higher cut rate, this new vitrectomy probe allows the cutting port to get closer to the retina but protects the retina to minimise complications
"In addition, the new probe allows for enhanced surgeon control because it has a smaller sphere of influence and it enables access to tissue planes. Based on its features, the ULTRAVIT® 10k vitrectomy probe should allow for better posterior vitreous detachment creation over the disc while also making delamination easier and enabling aspiration of blood,” said Dr Gotzaridis. The distance between the bottom of the probe and the port opening is shorter on the new bevel tip probes compared with the same gauge flat-tipped probes, measuring just 0.009 inches for all probes in the series versus 0.016 inches to 0.021 inches on the flat-tipped counterparts. And the bevel tip design further reduces the effective port-to-retina distance. For a 23-gauge probe, the bevelled probe provides 57% closer proximity to the retina when held at a 60° tangential angle compared with the flat-tipped probe. Using the 25+ and 27+ gauge bevel tip probes, the distance between the cutting port and retina is reduced by 50% and 44%, respectively, compared with standard flat-tipped probes. Stratos Gotzaridis: stratosgotzaridis@yahoo.com
Latest Articles
From Lab to Life: Corneal Repair Goes Cellular

Long-awaited cellular therapies for corneal endothelial disease enter the clinic.

Read more...

Balancing Innovation and Safety

Ensuring access to advanced cell therapies amid regulatory overhaul.

Read more...

With Eyes on Its Future, ESCRS Celebrates Its Past

Winter Meeting offers opportunities to experiment with new concepts and formats.

Read more...

Best of ESCRS Winter Meeting 2024

Read more...

Following the New Generation

EDOF IOLs an option for eyes with mild comorbidities, showing potential in mini-monovision strategies.

Read more...

Refocus on Multifocals

Trifocal IOLs continue to improve as consensus grows regarding indications and contraindications.

Read more...

Common Myths in Presbyopia Correction

Patient education key to satisfaction with refractive IOLs.

Read more...

Reversible Multifocality

Two-lens combination offers low-risk spectacle independence for cataract patients and presbyopes.

Read more...

Managing a Cataract Surgery Refractive Miss

Weighing the pros and cons of options for intraocular intervention.

Read more...

Unleashing OCT’s Full Potential

Performance of newest tool for corneal evaluation meets or beats older standard technologies.

Read more...

;